| Rezime: |
| The paper is focused on the analysis, redesign and rehabilitation solutions
applied for old existing structures in seismic zones. The old malting building, erected
between 1857-1876 at the “Timisoreana” Brewery, is a five storeys masonry structure
and a tower composed of: walls of (140-50) cm thickness; inter-storey floors - brick
masonry vaults supported by steel profiles; a tower, of about 14 m height and 2.80 m
diameter, supported by an interior dome. The main structural damages were: vertical
cracks in the tower masonry structure; corrosion of steel members – horizontal circular
rings for confining the tower; steel profiles for supporting the floor masonry vaults. The
static and dynamic analysis at different actions showed up major structural
vulnerability, mainly due to the period of design and erection (19th century). In order to
preserve the old building as architectural monument and to reduce the seismic failure
risk, some strengthening solutions were designed and applied. The strengthening
solutions were selected in order to obtain technical and economical advantages: safe
behaviour at seismic actions; slight change of overall structural stiffness; easy
strengthening technology and short refurbishment period; low rehabilitation cost. |
|
| Ključne reči: |
| masonry structures; old buildings; seismic zones; stability; strengthening
solutions; carbon fibre reinforced polymers (CFRP) |
|
|
|