CONFERENCE PROCEEDINGS
7th INTERNATIONAL CONFERENCE
CONTEMPORARY ACHIEVEMENTS IN CIVIL ENGINEERING 2019 , 2019.y., pp. 3-11
EVALUATION OF STRUCTURAL ELEMENTS AFFECTED BY FIRE |
|
DOI: 10.14415/konferencijaGFS2019.000 |
UDC: 614.845:728.5+699.81 |
CC-BY-SA 4.0 license |
Author : Bujňák,Ján; Jedraszak, Bronisław |
|
| Summary: |
| Fire poses a serious threat to living creatures and to the environment.
Without proper controls, even minor errors or defects can quickly lead to major disaster.
Presently, numerical and experimental investigations have provided calculation rules for
the assessment of the carrying capacity of building components in the event of a fire.
Actually, the remaining resistance of structure, depending on time exposure to fire can
be evaluated using the current geometry, material and section design characteristic as
well as information on fire development provided by fire-fighting crew. Beside the load
bearing functions, the separation or insulation criterions could be important. The paper
deals with the above mentioned passive fire measurements. Particular emphasis is
placed on damage assessments and suitability of structure affected by a fire, illustrated
on the case study. |
|
| Keywords: |
| Fire resistance, evaluation of remaining load capacity, testing. |
|
|
|