CONFERENCE PROCEEDINGS
4th INTERNATIONAL CONFERENCE
CONTEMPORARY ACHIEVEMENTS IN CIVIL ENGINEERING 2016 , 2016.y., pp. 51-58
DESIGN OF WALL DIAPHRAGMS ACCORDING TO EC 5 |
|
DOI: 10.14415/konferencijaGFS 2016.107 |
UDC: 674.11.046 |
CC-BY-SA 4.0 license |
Author : Stojić, Dragoslav; Cvetković, Radovan; Conić, Stefan; Marković, Nemanja |
|
| Summary: |
| This paper presents basic concept for analyzing shear wall diaphragms in
timber frame structures – platform frame construction. It also provides important
instructions and notes on the factors that may have influence on the racking resistance
of vertical panels. Providing lateral and torsional stability of high – storey buildings
made of timber, in general, is achieved by bracings and / or formation of the roofs,
floors and wall diaphragms. The basic requirements that must be met according to
ultimate limit state are: static equilibrium and racking resistance of wall panels. For the
racking design of timber diaphragms Eurocode 5 provides two simplified methods
(Method A and Method B). The goal of the analysis is to show different aspects of modern calculation methods and their effectiveness compared to a traditional approach to the problem. |
|
| Keywords: |
| Shear wall, Eurocode 5, racking resistance |
|
|
|